东京久久,人人精品久久,毛片免费全部播放1000部,人人澡人人模人人爽手机版,美女视频黄的全免费无遮挡,日本在线美女视频,杨幂的那个视频

 

 

 HEBEI WELDING EQUIPMENTS CO., LTD

 

 

   BX3 Series AC Arc Welding Machine

     Welding-machines of series BX3 which using move-coil structure can manually weld moderate and low-alloy steel part, it also can be used in electric arc cutting. With such properties as electric current's constant adjusting,stable and reliable performance and low failure rate, it applies to mining industry and enterprise production .         

First. Use

BX3 series moving circle AC arc welding machines for single hand. 3-30mm thick in the welding of low carbon steel and low alloy steel, and a variety of mechanical structures, use  1.5-6 mm rod, in the whole scope of the current regulation can keep stable welding arc welding spatter small, Weld smoothing. The structure may be filled work also.

Second. The main technical data

Type

Units

BX3-300-3

BX3-300

BX3-500

BX3-500-2

The initial voltage

V

380

scope of the current regulation

 Connection

A

36-125

60-134

70-185

70-224

 Connection II

120-360 

120-360 

172-520 

222-610 

No-load voltage

 Connection

V

75

78

78 

78 

Connection II

65 

70

69

70

Voltage

V

22-35

22.4-35

22.8-40.8

22.8-44

Efficiency

85

85

84

88.5

Rate for  Power Factor

 

0.51 

0.51 

0.62 

0.61

 Frequency

Hz

50

The rate of duty

100

35

100

35

100

35

100

60 

Input volume

KVA

12.2

21

13

22

22.42

88

28.5

36.86

The primary current

A

32

55

34

58

59

100

75

97

 Secondary current

A

177

300

178

300

296

500

387

500 

Pleasing dimensions (L×W×L)

mm

630×480×810

720×540×900

650×490×850

720×540×900

Weight

kg

115

164

180

235

 

 

 

 

 

 

 

 

 

 

 

 

A continuous load current rate of welding and welding cycle than access time. =t/T*100% loading rate is sustained, "t" for the welding current access time "T" for the entire period (the sum of working hours and rest periods) cycle 5 minutes.

Third. The adjustment of welding current

   Welding current regulator for the two tranches, Ⅰ, Ⅱ followed by the combination of two tranches for a complete switch. Fine adjustment of welding current rotation on the handle conditioning coil position, and change the size to achieve leakage reactance.

Fourth. The attention

1、Pre-operational check carefully whether the nut tightening wiring, grounding grounding line reliability.

2、The welding process, seeking Combined Switch shift, we must stop welding, the welding process must not shift!

3、The use of welding, the welding machine welding current than allowed welding value.

4、Welder not by rain, snow-drenched, should be placed on a dry place.

Fifth. BX3 series welding machines and methods to Common

 

Fault

Why cause

Elimination

Lead superheated Connection

Connection contact resistance is too big wiring Department ban firmware is too lax.

 

Loose wiring, use sandpaper or a knife Department will contact conductive metallic sheen sorted out, then screw screw or nut ban.

Welder overheating

1、Transformer overload

2、Transformer short-circuit

3、Core screw insulation damage

 

1、Reducing the use of current, in accordance with the regulations load operation;

2、The elimination of short-circuit;

3、Recover insulation.

Electrical shell welder

1、Primary or secondary winding winding collision shell;

2、The power line collision shell;

3、Welding cable collision shell;

4、Grounding not or grounding bad.

1、Check and eliminate collision shell;

2、To eliminate collision shell;

3、Eliminating collision shell;

4、And then make good contact with a good grounding line.

Welder insufficient voltage

1、The secondary winding is short;

2、The low voltage power supply;

3、Power lines are too thin, too much pressure drop;

4、Welding cable is too small, too much pressure drop;

5、Bad contact.

1、The elimination of short-circuit;

2、Adjust voltage to fixed value;

3、The replacement of thick line supply;

4、The replacement of thick cables;

5、To make good contact joints.

Welding current is too small

1、Welding cables is too long ;

2、Welding cable disk into two types, large inductance;

3、A cable joints or  to the workpiece is not good.

1、Or to increase the length of the cables to reduce cable diameter;

2、Cables from the disk should be open;

3、Joint good contact, contact with the workpiece good.

Welding current instability

Have access to the workpiece and welding cables is not good.

Welding cables make good contact with the workpiece.

Welder output current is unusual, too large or too small.

1、The circuit plays the role of the inductive loop coil insulation damage caused excessive current;

2、Core alternating Whirlpool insulation damage caused Current too small.

1、Circuit insulation inspection, troubleshooting;

2、The magnetic circuit insulation inspection, troubleshooting.

Welding strong ring for buzzing

1、Secondary coil short- circuit;

2、Sub-circuit current, or use too much overload.

1、Check and eliminate short-circuit;

2、Check and eliminate short-circuit, reducing the use of current and avoid the use of overload.

Welder is not the normal noise

1、The safety net by the electromagnetic vibration;

2、Box screw loose shell;

3、And side cover after cover the latter;

4、Machine screws, nuts loose.

1、To check the noise and vibration;

2、tightening screw shell boxes;

3、Check and eliminate the latter;

4、Opened the side cover screening and tightening screw nut.

Fuse broken

1、The latter joint power line;

2、Short-circuit electrical wiring joints collision shell;

3、Broken power lines joint ground.

1、Check and eliminate short-circuit;

2、Check and eliminate short-circuit;

3、Replace or repair power lines.

Sixth. BX3 series welding machines to the regular maintenance :

No.

Content

Requirements

1.

The opening of a new long-term use or not to use the welder welder, careful inspection and test welder.

Welder no damaged property (if any damage should be repaired) with the products or the technology (ZBJ64006-88)

2.

1、The debris cleaning machine outside;

2、Compressed air blowing dust net external machine.

Clean and tidy.

3.

Screw fasteners and other parts of the examination.

Other parts of the screw fasteners.

4.

Ground inspections and connect

Good grounding, correct wiring.

5.

Screw smear regulation is appropriate and lubricants increases

Adjusted reliable.

6.

Check wire, insulation and welder Power Switch

1、Paper damaged wire insulation was applied in the vulcanization of rubber or plastic insulation special bandage.

2、Welder early secondary winding insulation resistance of> 0.5 and 0.2 Megohm above, it shall be dry, to repair the defects.

3、The switch should contact a good contact.

7.

Repair welding clamp

Welding clamp and  cable connecting dependable, and pursue good insulation.

Seventh. Sets supply

1、One BX3 AC arc welder

2、One Pass masks

3、One factory certified

4、One welding clamp

5、One the use of brochures

6、Welding cable 20 meters (including two joints)

Models

BX3—300—3

BX3—300

BX3—500

BX3—500—2

Cable specifications

25 mm square

35 mm square

35 mm square

50 mm square

Joint specifications

300A

300A

500A

500A

 

 

   

back